Tampa Low-Slope Re-Roof Inspection: Drip Edge and Wall Flashing on a Modified Bitumen Roof
November 25, 2026 · Enrique Lairet, PE
An example from an after-the-fact re-roof inspection in Tampa, Florida: two low-slope roofs, a modified bitumen roof system, and the edge and flashing details that decide whether water stays out.
The Project: Two Low-Slope Roofs, One Re-Roof
The home has two roof areas that meet at one corner. The main roof has a slope of about 2:12 (two inches of rise per foot). Below its eave, a lean-to patio roof is much flatter, close to level.
Both roofs were re-roofed with a modified bitumen system, and the re-roof needed an inspection after the work was finished. Oasis Engineering performed an on-site inspection to document the installed roof, with particular attention to the roof edges and the place where the low patio roof meets the wall below the main roof's gutter.
Why Modified Bitumen on a Low-Slope Roof
Slope decides which roof coverings the Florida Building Code allows.
- Asphalt shingles need a slope of at least 2:12 (Florida Building Code, Residential, Section R905.2.2), and slopes from 2:12 up to 4:12 need the low-slope underlayment method. A 2:12 roof is at the very bottom of that range.
- Modified bitumen is a membrane roof. It needs a design slope of only 1/4 inch per foot for drainage (Section R905.11.1), which is why it is the usual choice for a nearly flat patio roof.
Modified bitumen sheets must meet the ASTM standards listed in Section R905.11.2 (such as ASTM D6162, D6163 and D6164), and Section R905.11.3 requires the roof to be installed according to the manufacturer's instructions. In Florida, roofing products also carry a Florida Product Approval (Rule 61G20-3, Florida Administrative Code), and the approval document lists how that system is to be installed.
Tampa is outside the High-Velocity Hurricane Zone, so the Miami-Dade and Broward roofing application standards do not apply here. The Florida Building Code and the manufacturer's instructions govern.
The Metal Drip Edge
The drip edge is the bent metal at the roof edge. It does two jobs: it carries water off the roof and past the fascia, and it holds and protects the edge of the roof membrane, which is where wind starts to lift a roof.
On a modified bitumen roof, the metal edge is typically set on the base sheet, fastened to the deck, primed and then stripped in, so that the cap sheet or a separate strip of membrane seals over the metal flange. The exact sequence, the primer and the fastener spacing come from the roofing manufacturer's instructions and the product's Florida Product Approval, not from one fixed rule. (The detailed drip edge dimensions in Section R905.2.8.5 of the residential code are written for shingle roofs.)
For low-slope membrane roofs designed under the Florida Building Code, Building, the metal edge itself must be designed and tested to resist wind (Section 1504.5, which references the ANSI/SPRI ES-1 test standard).
During the inspection we look at:
- Whether the metal edge is continuous, with the joints between pieces lapped.
- Whether the membrane laps onto the flange and is sealed to it, with no open edge the wind can catch.
- Whether the drip edge projects past the fascia so water drips clear instead of running back onto the wood.
- The corners, where two edges meet and gaps are most common.
The Wall Flashing Where the Patio Roof Meets the Wall
The photo at the top of this article shows that corner. Above is the main roof's edge and gutter; below, the patio roof surface runs into the wall, where the granulated flashing turns up the vertical face.
Wherever a roof meets a wall, the code requires flashing (Section R903.2.1 lists wall and roof intersections and changes in roof slope or direction). Metal flashing must be corrosion-resistant and not lighter than No. 26 gauge galvanized steel.
On a modified bitumen roof, the flashing at a wall is usually a base flashing: the membrane turns up the wall several inches. That flashing is then covered at the top by a counterflashing, trim or siding, so water running down the wall lands on top of the flashing instead of behind it.
This corner is the most important part of this roof. It collects the water from the main roof's gutter area, it collects leaves and debris (visible in the photo), and the patio roof's low slope means water moves off it slowly. During the inspection we checked:
- That the flashing turns up the wall continuously at the corner, without a cut or open lap.
- That the top of the flashing is covered or sealed so water cannot get behind it.
- That the roof edge and the wall trim meet without an open gap at the corner.
- Signs of standing water, staining or soft decking near the junction.
What an After-the-Fact Re-Roof Inspection Covers
A re-roof permit normally has inspections during the work, before the roof covering hides the deck, the fasteners and the underlayment. When those inspections are missed, the building department may accept an inspection and letter or affidavit from a Florida-licensed engineer instead.
An after-the-fact inspection is limited to what can be seen and what can be documented:
- Visible conditions: the finished roof surface, the edges, the flashing, the slope and drainage.
- Records: the permit, the Florida Product Approvals for the installed products, invoices, and photos taken during installation.
- What cannot be seen: deck fastening, the base sheet and underlayment under the finished roof. These are evaluated only as far as photos and records support them; otherwise they are excluded or verified in a limited, targeted way.
Whether a letter can be issued depends on what the inspection finds and on the evidence available. The building department makes the final decision on the permit.
Frequently Asked Questions
What is the minimum slope for a modified bitumen roof in Florida? 1/4 inch per foot, under Florida Building Code, Residential, Section R905.11.1. Below 2:12, asphalt shingles are not allowed, so membrane systems such as modified bitumen are the usual choice.
Is a drip edge required on a modified bitumen roof? The metal edge is part of the roof system, and its installation follows the manufacturer's instructions and the product's Florida Product Approval. For low-slope membrane roofs under the Florida Building Code, Building, the metal edge must also resist wind (Section 1504.5, ANSI/SPRI ES-1).
What does an engineer check at a roof-to-wall joint? That flashing is installed where the roof meets the wall, that it is continuous at corners, and that it is covered or sealed at the top so water cannot get behind it (Section R903.2.1).
Can an engineer inspect a re-roof after the work is finished? Yes, within limits. The engineer documents what is visible and what the records show. Concealed work is evaluated only as far as the evidence supports, and acceptance remains with the building department.
Need a Re-Roof Inspection in the Tampa Bay Area?
If your re-roof permit has a missed inspection, or you need an engineer to document a low-slope roof, Oasis Engineering can help. A Florida-licensed professional engineer inspects the roof and prepares letters and reports when the evidence supports them.
Contact Oasis Engineering to describe your roof and the building department's request.
Related: St. Petersburg engineer affidavit for stucco wire lath, without demolition
Engineering letters: engineerletters.co
Disclaimer: This article describes one inspection and general code provisions for education. Code sections are from the Florida Building Code, 8th Edition (2023); check the edition and any local amendments that apply to your permit. The installation of a specific roof system follows its manufacturer's instructions and Florida Product Approval. Findings and the availability of a letter depend on the project conditions, the evidence available and the building department's requirements.