Aerospace & ground facilities
Engineering for the ground side of space.
Equipment anchorage, pads, shelters and antenna foundations for aerospace suppliers, contractors and facility teams. Sealed calculations and details, built for coastal wind and flood.
ASCE 7
Wind, flood and seismic loads
ACI 318
Anchoring to concrete
FBC 2023
Florida Building Code
Sealed
Signed by a licensed PE
Why it matters
The equipment is engineered. What holds it down often isn’t.
A test skid, a generator enclosure or a ground-station antenna arrives with a manufacturer’s cut sheet. How it attaches to the site is usually left to the project: the anchor bolts, the pad under it, the slab it lands on, the shelter around it.
On a coastal site that connection has to resist hurricane wind and sit above the flood level, and a reviewer will want sealed calculations behind it. That is the part we engineer, sized to the real loads instead of a rule of thumb.
What we engineer
From one anchor pattern to a whole equipment yard.
Equipment anchorage
Skids, enclosures, tanks, racks, generators and ground-support equipment: anchor bolts, embedment and edge distances checked for wind, and seismic where it applies.
Equipment pads & slab checks
Can the existing slab carry the new load? We check it, or design a new pad or foundation sized for the equipment and the site.
Modular shelters & containers
Container and modular buildings for equipment, storage, test or office use: tie-downs, piers and foundations, the same work behind our container builds.
Antenna & mast foundations
Dishes, masts and small towers: wind on the reflector or mast, overturning and sliding, and the footing that resists them.
Facility retrofits
New openings, roof-mounted equipment, platforms and framing changes in existing hangars, warehouses and shops.
Storm & flood hardening
Coastal sites: wind-rated openings, rooftop equipment tie-downs and equipment raised above the design flood elevation.
Existing-condition surveys
Site visit, measurements and a 3D scan when there are no drawings, so the design starts from what is actually built.
Installation inspections
An engineer on site to confirm the anchors, pads and tie-downs went in as designed, with a sealed letter and photos.
A good first job
Equipment anchorage & foundation package
One piece of equipment, one site, one sealed package: the loads on the equipment, the anchor design, the pad or slab check and the installation details your contractor builds from.
- 1
Send the equipment and the site
Cut sheets, the address or site criteria, and what you know about the slab.
- 2
We run the loads and checks
Wind, flood and seismic as they apply; anchors to concrete; the pad, slab or foundation.
- 3
You get sealed calcs and details
Calculations and installation details, signed and sealed, ready for the permit or the site’s engineering review.
What to send
- Equipment cut sheets: weight, center of gravity, footprint and anchor pattern
- Site address, or the facility’s design criteria if the site has its own
- Slab or foundation drawings, if any (photos are a good start)
- The deadline and who reviews the drawings
Also for data centers, telecom shelters and utility sites: the loads and the checks are the same.
Start a requestQuestions
What do you need to start?
The equipment data (weight, center of gravity, footprint and anchor locations from the manufacturer’s cut sheet), the site address, and whatever you have on the slab or foundation. If there are no drawings, we can measure on site; slab thickness and reinforcement may need a scan or a core.
Do you design the equipment itself?
No. We engineer what holds it: the anchorage, pads, foundations, shelters and the building framing it sits on. The equipment’s internal design stays with its manufacturer.
Our site has its own design criteria. Can you work to them?
Yes. Some sites, including many on federal property, follow the owner’s own design criteria instead of a county permit. Send the criteria you were given and we check against them along with ASCE 7 and the governing code.
Is this only for aerospace?
No. The same work applies to data centers, telecom shelters, utility and industrial sites: anything heavy that has to stay put in wind, flood or seismic loading.
Where do you work?
Across Florida, including the Space Coast, and in the other states where we are licensed. The intake checks licensure for your site first.